Description
OUTPUT DATA | Technical Specification |
AC nominal output (Pac,r) |
5000 W |
Max. output power (Pac max) |
5000 VA |
AC output current (Iac nom) |
21,7 A |
Grid connection (Uac,r) |
1~ NPE 220/230 V |
AC voltage range (Umin – Umax) |
180 – 270 V |
Frequency (fr) |
50 / 60 Hz |
Frequency range (fmin – fmax) |
45 – 65 Hz |
Total harmonic distortion |
< 5 % 5=”” %=””> |
Power factor (cos φac,r) |
0,85 – 1 ind./cap. |
GENERAL DATA | |
Height | 645 mm |
Width | 431 mm |
Depth | 204 mm |
Weight | 21,5 kg |
Degree of protection | IP 65 |
Protection class | 1 |
Overvoltage category (DC / AC) 1) |
03-Feb |
Night-time consumption | < 1 w 1=””> |
Inverter design | Transformerless |
Cooling | Regulated air cooling |
Installation | Indoors and outdoors |
Ambient temperature range | -40°C – +55°C |
Permitted humidity | 0 – 100 % |
Max. altitude 2) |
4.000 m |
DC connection technology | 4x DC+ and 4x DC- screw terminals 2.5 – 16 mm² |
AC connection technology | 3-pin AC screw terminals 2.5 – 16 mm² |
Certificates and compliance with standards | DIN V VDE 0126-1-1/A1, IEC 62109-1/-2, IEC 62116, IEC 61727, |
AS 4777-2, AS 4777-3, G83/2, G59/3, CEI 0-21, VDE AR N 4105 | |
EFFICIENCY | |
Max. efficiency (PV – grid) | 98,10% |
European efficiency (ηEU) | 97,10% |
η at 5% Pac,r 3) |
80,8 / 82,5 / 82,5 % |
η at 10% Pac,r 3) |
89,6 / 94,8 / 93,1 % |
η at 20% Pac,r 3) |
93,4 / 97,2 / 96,2 % |
η at 25% Pac,r 3) |
94,1 / 97,3 / 96,8 % |
η at 30% Pac,r 3) |
94,7 / 97,4 / 97,0 % |
η at 50% Pac,r 3) |
95,8 / 97,9 / 97,7 % |
η at 75% Pac,r 3) |
96,1 / 98,0 / 97,9 % |
η at 100% Pac,r 3) |
96,2 / 97,9 / 97,9 % |
MPP adaptation efficiency | > 99,9 % |
PROTECTION DEVICES | |
DC insulation measurement | Yes |
Overload behaviour | Operating point shift, power limitation |
DC disconnector | Yes |
INTERFACES | |
WLAN / Ethernet LAN | Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) |
6 inputs and 4 digital inputs/outputs | Interface to ripple control receiver |
USB (type A socket) 4) |
Data logging, inverter update via USB flash drive |
2x RS422 (RJ45 socket) 4) |
Fronius Solar Net |
Signalling output 4) |
Energy management (floating relay output) |
Datalogger and web server | Integrated |
External input 4) |
S0 meter connection / Evaluation of overvoltage protection |
RS485 | Modbus RTU SunSpec or meter connection |
Reviews