Technical Specification
|
Number of MPP trackers
|
1
|
Max. PV input power
|
5000 W
|
Max. input current (Idc max)
|
1 x 16 A
|
Max. short circuit current, module array
|
24 A
|
DC input voltage range (Udc min – Udc max)
|
150 – 1000 V
|
Feed-in start voltage (Udc start)
|
200 V
|
Nominal input voltage (Udc,r)
|
595 V
|
MPP voltage range (Umpp min – Umpp max)
|
200 – 800 V
|
Usable MPP voltage range
|
150 – 800 V
|
Number of DC connections
|
2
|
BATTERY INPUT
|
|
Maximum output power to battery
|
Dependent on connected Fronius Solar Battery
|
Maximum input power from battery
|
Dependent on connected Fronius Solar Battery
|
OUTPUT DATA
|
|
AC nominal output (Pac,r)
|
3000 W
|
Max. output power (Pac max)
|
3000 VA
|
Max. grid power demand
|
3000 VA
|
Max. AC output current
|
8,3 A
|
Grid connection (Uac,r)
|
3~ NPE 400/230, 3~ NPE 380/220 V
|
AC voltage range (Umin – Umax)
|
150 – 280 V
|
Frequency (fr)
|
50 / 60 Hz
|
Frequency range (fmin – fmax)
|
45 – 65 Hz
|
Total harmonic distortion
|
< 3 % 3=”” %=””>
|
Power factor (cos φac,r)
|
0,85 – 1 ind./cap.
|
GENERAL DATA
|
|
Height
|
645 mm
|
Width
|
431 mm
|
Depth
|
204 mm
|
Weight
|
19,9 kg
|
Degree of protection
|
IP 65
|
Protection class
|
1
|
Overvoltage category (DC / AC) 1)
|
03-Feb
|
Night-time consumption
|
< 1 w 1=””>
|
Inverter design
|
Transformerless
|
Cooling
|
Regulated air cooling
|
Installation
|
Indoors and outdoors
|
Ambient temperature range
|
-25°C – +60°C
|
Permitted humidity
|
0 – 100 %
|
Max. altitude 2)
|
2.000 m
|
DC PV connection technology
|
2x DC+ and 2x DC- screw terminals 2.5 – 16 mm²
|
DC battery connection technology
|
1x DC+ and 1x DC- screw terminals 2.5 – 16 mm²
|
AC connection technology
|
5-pin AC screw terminals 2.5 – 16 mm²
|
Emergency power compatible
|
Yes
|
Certificates and compliance with standards
|
VDE AR N 4105, ÖVE / ÖNORM E 8001-4-712, DIN V VDE 0126-1-1
|
EFFICIENCY
|
|
Max. efficiency (PV – grid)
|
97,70%
|
Max. efficiency (PV – battery – grid)
|
> 90,0 %
|
European efficiency (ηEU)
|
95,20%
|
η at 5% Pac,r 3)
|
78,5 / 77,3 / 66,9 %
|
η at 10% Pac,r 3)
|
83,1 / 83,8 / 76,6 %
|
η at 20% Pac,r 3)
|
90,0 / 93,0 / 90,6 %
|
η at 25% Pac,r 3)
|
91,2 / 93,9 / 91,9 %
|
η at 30% Pac,r 3)
|
92,4 / 94,7 / 93,3 %
|
η at 50% Pac,r 3)
|
94,5 / 96,7 / 96,0 %
|
η at 75% Pac,r 3)
|
95,1 / 97,3 / 96,6 %
|
η at 100% Pac,r 3)
|
95,4 / 97,7 / 97,0 %
|
MPP adaptation efficiency
|
> 99,9 %
|
PROTECTION DEVICES
|
|
DC insulation measurement
|
Integrated
|
Overload behaviour
|
Operating point shift, power limitation
|
DC disconnector
|
Integrated
|
Integral RCMU
|
Yes
|
INTERFACES
|
|
WLAN / Ethernet LAN
|
Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
|
Datalogger and web server
|
Integrated
|
Interface to battery and meter
|
Modbus RTU (RS485)
|
Reviews